www.nulec.com.au
Power Division Home | Careers | News | Feedback
  1. Solutions
    • Customised Solutions
    • - Automated Solutions
    • - Loop Automation
    • - ACO
    • - Sectionalisers
    • - WSOS Alert System
    • - WSOS Remote Control
    • - Generator Control
    • - Ready To Go Units
    • - Application Notes
    • - Technical Tips
  2. Products and Services
    • Products Introduction
    • Product Offer
    • - N-Series Recloser
    • - U-Series Recloser
    • - W-Series Recloser
    • - RL-Series Load Break Switch
    • - PTCC Controller
    • - ADVC Controller Range
    • - Configuration Software
    • Accessories
    • Services Introduction
    • - Equipment Support
    • - Training Courses
    • - Product Application Support
  3. Support
    • Contact Us
    • About Schneider
    • Our Brand History
    • About Us
    • Trade Shows
    • Quality Assurance
    • Safety Policy
    • Environmental Policy
    • Frequently Asked Questions
    • Research and Development
    • Manufacturing
  4. Downloads
    • Download WSOS 4
    • Download WSOS 5
    • Videos
  5. Service Log In
    • Log In

Loop Automation

Popular Links

Newsletter May 2010
Newsletter September 2008
ADVC Controller Range Video Now Available!
ADVC Controller Range Supports DNP over IP
Exhibition for a Smart Future

Global Recloser Solutions

Loop Automation

How do you reduce customer minutes lost ?

Recloser Solutions' Loop Automation is a Distribution System Automation Scheme designed to restore supply to customers in the shortest possible time.

Using standard recloser features, the Loop Automation Scheme reconfigures protection settings, sectionalises faults, minimises affected areas, and restores network supply without the need for communications or operator intervention.

Loop Automation automatically reconfigures a feeder network affected by an outage when an alternative source of supply is available. The alternative source is typically a second feeder connected via a normally open point. The normally open recloser that ties the feeders together is known as the Tie recloser. Other reclosers are labelled Feeder recloser for the one closest to the substation, and Mid-Point reclosers are those between the Feeder and Tie reclosers.

Each of the reclosers in a loop automation scheme is programmed to behave in accordance with a set of logic rules specific to its location on the network.

Communication is not required for a loop automation network and power is restored to the healthy parts of the network by using: n Voltage sensing at each bushing (determine the loss of supply); n Logical rules (specific to each recloser position) to determine the recloser's action; and n User configurable timer (a delay to systematically reconfigure each recloser when required).

The diagram below shows the basic configuration of a loop automation network.


The basic network reconfiguration action taken by each recloser in the network can be summarised as follows:
  • Feeder recloser - Opens when supply is lost on the source (substation) side of the recloser.
  • FMid-point recloser - When supply is lost the controller changes the direction of protection anticipating power flow in the opposite direction.
  • FTie recloser - Closes when supply is lost on the one side of the recloser.

    Download the interactive Loop Automation Demonstration Program to see many of the scheme's key operating features. Simulate trip, reclose, and Loop Automation sequences in reaction to user initiated faults.

    Download the Loop Automation Software - Windows 98/2000/NT/XP
  • Did You Know

    Configurable Quick Keys

    Quick Keys provide the capability for the operator to quickly access and change commonly used operator settings without having to navigate to a particular screen. The new version 2.... more

    Click here for more Tips
     